• For Outdoor Monitoring

    The protective housing can withstand temperatures between -30° to 50°C, providing a high level of protection against challenging environmental conditions and theft.

  • Simplify Integration

    Multiple communication and control options enable easy integration into standard security and IiOT solutions including HMI/SCADA, ONVIF, Modbus, MQTT, and REST API protocol.

  • Consistent, Accurate Results

    With up to 640 × 480 thermal resolution, remote motor focus, FSX® (Flexible Scene Enhancement) technology, and three fields of view, A500f/A700f cameras provide reliable measurements every time.

Specifications
General
Housing material
Aluminium housing, sunshield in ABS
Mounting
Bought separately, pole and wall adaptors available
Overview
Encoding
Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric
Focal Length
29 mm
Heater
8W, electronically controlled, T_ON 20°C±2°C (68°F±4°F), T_OFF 23°C±2°C (73.4°F±4°F)
Multi-Streaming
Yes
Window Transmission
Automatic Compensation
System Overview
Focal Plane Array (FPA)
Uncooled microbolometer
Size (L x W x H)
51.5×17.7×22.9 cm (20.28×6.97×9.02 in)
Compliance & Certifications
ONVIF Conformance
Yes. ONVIF Profile S
Connections & Communications
Multicast
Yes
RS-232
M8 A-coded, male connector directly on camera, inside housing
Electrical & Mechanical
Cable Glands
1xM12, 1xM16, 1xM20
Environmental & Approvals
EMC
EN50130-4, EN61000-6-3, EN55022 Classe B, FCC Part. 15 Class B
Encapsulation
IP67
Operating Temperature Range
-30°C to 50°C (-22°F to 122°F)
Imaging & Optical
Contrast Enhancement
FSX® / Histogram equalization (IR only)
f-number
1.5
iFoV
0.52 mrad/pixel
Image Fequency
30 Hz
Minimum Focus Distance
1.0 m (3.28 ft)
MSX
Yes
Overlay
With / Without
Radiometric IR video streaming
RTSP protocol to FLIR Atlas SDK
Readout
Measurement results: • Ethernet/IP • Modbus TCP server (pull) • Modbus TCP client (push) • MQTT (push) • REST API (GET/POST) • Measurements and still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960) • Web interface
Spectral Range
7.5–14 µm
Visual Resolution
1280 × 960
Measurement & Analysis
Automatic hot & cold detection
Max./min. temperature value and position shown within box
Measurement Presets
Yes
Measurement Tools
10 spotmeters, 10 boxes or mask polygons, 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline Maximum 12 measurement functions at the same time.
Measurement & Analysis
Atmospheric transmission correction
Based on inputs of distance, atmospheric temperature, and relative humidity
Measurement Corrections
Global object parameters; local parameters per analyze function
Object Temperature Range
–20° to 120°C (–4° to 248°F) 0° to 650°C (32° to 1202°F) 300° to 1500°C (572° to 2732°F)
Other
Web interface
Yes
Performance
Accuracy
±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15° to 35°C (59° to 95°F) and object temperature above 0°C (32°F)
Physical
Package Dimensions [L × W × H]
62 × 20.2 × 22 cm (24.41 × 7.92 × 8.66 in)
Power
Power Consumption
30W PoE,  PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus
Storage Media
Image Storage
Records up to 100 FLIR radiometric JPEG; storage as function of: alarm, scheduling, or user interaction (camera web)
System Integration
Alarm Functions
On any selected measurement function, digital in, and internal camera temperature
Alarm Output
• Digital out • E-mail (SMTP) (push) • Ethernet/IP • File transfer (FTP) (push) • Modbus TCP server (pull) • MQTT (push) • Query over RESTful API (pull) • Store image or video
Digital I/O connector type
Terminal block inside housing
Digital I/O isolation voltage
500 VRMS
Digital input purpose
NUC, NUC disable, alarm
Digital Inputs
2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
Digital Output Purpose
• As a function of alarm, output to external device • Fault (NC)
Digital Outputs
3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
Ethernet
For control, result, image, and power
Ethernet Communication
TCP/IP socket-based FLIR proprietary
Ethernet Connector Type
IP67 rated RJ45 port
Ethernet Interface
Wired
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 3
Ethernet Protocols
• EtherNet/IP • IEEE 1588 • Modbus TCP • MQTT • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP
Ethernet Standard
IEEE 802.3
Ethernet Type
10/100Base-T
Streaming Resolution
Video stream 0: 640 × 480 pixels Video stream 1: 1280 × 960 pixels Radiometric stream: 464 × 348 pixels
Thermal Imaging
Focus
Motorized focus, manual & on-command automatic (scene contrast method)
Video & Recording
Video Streaming
RTSP protocol
Visible Camera
Detector Pitch
17 µm
Detector Time Constant
Typical 10 ms
IR Resolution
464 × 348
Media Gallery
Related Documents

FLIR A500f/A700f Advanced Smart Sensor - Model: A500f Advanced Smart Sensor 14°

Change Selection